AC Not Turning On
When the AC is not turning on, the cause is often a loss of power or a safety switch doing its job. Work through the thermostat, the breakers, the indoor unit's power switch and door, and the condensate float switch, in that order. If all of them check out and nothing starts, the fault is likely in the controls or the outdoor unit's electrical parts.
Leave the building first
A gas smell is not a repair request. Stop here and do this now:
A carbon monoxide alarm is not a repair request. Stop here and do this now:
- Get everyone out of the house, pets too, and leave the door open behind you.
- Do not switch lights, appliances or the thermostat on or off, and do not use a lighter, a match or a phone inside.
- From outside, call your gas utility's emergency line or 911.
- Stay outside until the utility or the fire department says it is safe to go back in.
After the home is cleared, a licensed technician can check the furnace, boiler or water heater. You can come back to this form then.
Nothing was sent. This form does not handle gas or carbon monoxide emergencies.
Sending your request
Please keep this page open. The form is locked so the request is not sent twice.
Your request was received
We passed it to a contractor in your area. If one accepts, they contact you using the phone number or email you gave. We cannot say how soon, and you are not required to hire anyone.
No reply after a few days? Check your spam folder, then use the contact page.
We could not send your request
Nothing was sent to a contractor. Your answers are still on this page. Try again in a moment.Online requests are not connected yet
The request form is not linked to a contractor network yet. Nothing you typed was sent or saved. Please call instead, or try again later.Signs to stop and leave it off
Short answer
No response at all usually means power or controls. The indoor fan running while the outdoor unit stays quiet points to the outdoor breaker, disconnect, contactor or capacitor. A tripped float switch from a clogged drain is a common hidden cause.
Check in this order
- STEP 1Thermostat screenA blank screen often means dead batteries or no power from the system. Replace batteries, then confirm Cool mode and a setpoint at least three degrees below room temperature.
- STEP 2Main panel breakersMost homes have one breaker for the furnace or air handler and a separate double breaker for the outdoor unit. Reset a tripped one once.
- STEP 3Furnace or air handler switchA switch on or near the indoor unit, often mistaken for a light switch, cuts power to the whole system.
- STEP 4Blower doorMany furnaces have a door safety switch. If the front panel was removed for a filter change and not seated fully, nothing will run.
- STEP 5Float switchA small switch on the drain pan or line shuts cooling off when water backs up. If the pan is full, the drain line is the problem. See AC leaking water.
- STEP 6Outdoor disconnectLook at the box on the wall next to the condenser. Make sure it is in the on position. Do not open the unit itself.
Indoor runs, outdoor does not
If you hear the indoor blower and feel air at the vents, but the outdoor fan and compressor stay silent, the problem is on the outdoor side. A tripped outdoor breaker is the simple case. Beyond that, a failed contactor, a weak capacitor, a burnt wire or a bad low-voltage connection between indoor and outdoor units are the usual suspects. The capacitor stores enough charge to hurt someone even with the power off, so that testing belongs to a technician. Running the system in this state just moves warm air around; switch it off. The AC capacitor replacement page covers that repair, and AC blowing warm air covers the related symptom where the fan runs without cooling.

Other reasons an air conditioner will not start
- Blown control fuse or transformerThe low-voltage circuit that powers the thermostat has a fuse on the control board. A short can blow it, and the thermostat goes dark.
- Thermostat failure or wiringAn old thermostat, a loose wire or a smart thermostat without a common wire can stop sending the signal.
- Compressor lockoutSome systems lock out after repeated faults and need a technician to find the reason before resetting.
- Pest damageChewed low-voltage wires between the house and the outdoor unit are common in some areas.
- Utility or power issuesAfter a storm or outage, a surge can damage the control board or contactor.
Requesting repair
When you request AC repair, say what you already checked and what you heard: no sound, a click, a hum or a fan with no compressor. That lets the technician bring likely parts. Cost depends on the part, the access and the time of the visit; the AC repair cost guide explains it. If the unit is old and the fault is the compressor, ask for both a repair price and a replacement estimate before deciding.
Related services and guides
Pages that continue this topic.
Questions
Why is my thermostat set to cool but the AC is not turning on?
Check the batteries, the breakers, the furnace switch and the blower door. If those are fine, a tripped float switch, a blown control fuse or a thermostat wiring fault are the next most common reasons.
Could a bad capacitor stop the AC from turning on?
Yes. Without a working capacitor, the outdoor fan and compressor may hum but not start. A technician should test and replace it because it can hold a dangerous charge.
My AC stopped after a power outage. What should I do?
Turn the thermostat off, reset any tripped breakers once, wait a few minutes, and turn cooling back on. If it still will not run, a surge may have damaged a control part.
How long should I wait for the AC to start after resetting?
Many systems have a built-in delay of up to about five minutes before the compressor starts. Wait at least that long before deciding it is not working.