Heat Pump Frozen
A heat pump frozen with a light coat of frost in winter is normal, and the unit melts it with a defrost cycle. A heat pump encased in solid ice, or one whose coil stays white for hours, has a problem: the defrost control, the outdoor fan, low refrigerant, or water dripping onto it from above. Do not chip at the ice. Switch the thermostat to emergency or auxiliary heat if it has that setting, clear snow away from the unit, and request service.
Leave the building first
A gas smell is not a repair request. Stop here and do this now:
A carbon monoxide alarm is not a repair request. Stop here and do this now:
- Get everyone out of the house, pets too, and leave the door open behind you.
- Do not switch lights, appliances or the thermostat on or off, and do not use a lighter, a match or a phone inside.
- From outside, call your gas utility's emergency line or 911.
- Stay outside until the utility or the fire department says it is safe to go back in.
After the home is cleared, a licensed technician can check the furnace, boiler or water heater. You can come back to this form then.
Nothing was sent. This form does not handle gas or carbon monoxide emergencies.
Sending your request
Please keep this page open. The form is locked so the request is not sent twice.
Your request was received
We passed it to a contractor in your area. If one accepts, they contact you using the phone number or email you gave. We cannot say how soon, and you are not required to hire anyone.
No reply after a few days? Check your spam folder, then use the contact page.
We could not send your request
Nothing was sent to a contractor. Your answers are still on this page. Try again in a moment.Online requests are not connected yet
The request form is not linked to a contractor network yet. Nothing you typed was sent or saved. Please call instead, or try again later.Ice, electricity and fallen limbs
Short answer
Frost that clears every so often with a cloud of steam is the defrost cycle working. Thick ice on the coil, the top or the fan blades that does not go away means the heat pump cannot heat properly and may be damaged if it keeps running.
What normal defrost looks like
In heating mode, the outdoor coil runs colder than the outdoor air, so moisture freezes on it on damp days near or below freezing. The heat pump senses this and switches to defrost for a few minutes: the outdoor fan stops, the coil warms, and you may hear a whoosh and see steam rising. Indoors, backup heat often comes on so the air does not feel cold. How often it defrosts depends on humidity and temperature, from fairly often in wet near-freezing weather to rarely on dry, very cold days. A thin layer of frost between cycles is fine. A block of ice is not.
Freezing looks different on each system
- Split heat pumpOutdoor unit with an indoor air handler. Winter icing appears on the outdoor coil; summer icing appears on the indoor coil and lines, the same as an AC.
- Ductless mini-splitOutdoor units ice in winter the same way. Indoor heads may stop blowing during defrost and blink a light.
- Dual fuel systemA heat pump paired with a gas furnace. The thermostat may switch to the furnace in deep cold, and a stuck defrost can leave the furnace carrying the load.

What to do with a frozen outdoor unit
- STEP 1Watch for one defrost cycleIf the coil is just frosted, give it 30 to 90 minutes. If it clears, things are working.
- STEP 2Switch to emergency heatIf ice is thick, setting the thermostat to EM heat or auxiliary heat stops the outdoor unit and uses backup heat. It costs more to run, so use it only until repair.
- STEP 3Clear snow and dripsBrush snow away from the sides and top, and fix overflowing gutters that drip onto the unit if you can do it safely.
- STEP 4Check the filter and ventsLow indoor airflow can upset the system. Replace a dirty filter and open registers.
- STEP 5Request serviceIf ice returns or never clears, a technician should check defrost controls and refrigerant.
Why a heat pump stays frozen
- Defrost control or sensorThe board or coil sensor that starts defrost fails, so ice keeps building.
- Reversing valveDefrost depends on this valve shifting. A stuck valve means no defrost and often no heat.
- Outdoor fan motorA failed fan or a fan relay that does not stop during defrost slows melting.
- Low refrigerantA leak makes the coil run too cold and frost heavily. The leak must be found; topping off only delays it.
- Site problemsGutter drips, drifting snow or a unit set too close to the ground can refreeze it faster than defrost can clear it.
Prevention and repair
Keep a foot or two of clearance around the unit, keep gutters above it flowing, and ask whether the unit should sit on a stand or riser in a snowy area. Fall maintenance should include a defrost test. Request help through heat pump repair; price factors such as refrigerant type and after-hours visits are on the heat pump repair cost guide. If the house is also cold, see heat pump not heating.
Related services and guides
Pages that continue this topic.
Questions
How do you unfreeze your heat pump?
Let the defrost cycle try first. If ice stays, switch the thermostat to emergency heat so the outdoor unit stops, clear snow around it, and call for service. Do not chip the ice.
How often should a heat pump go into defrost mode?
It depends on the weather and the control. In damp weather near freezing, defrost may run about every 30 to 90 minutes for a few minutes at a time. On cold, dry days it may be much less often.
What is the main drawback of a heat pump in winter?
Output and efficiency drop as outdoor temperatures fall, and in very cold weather many systems rely more on backup heat, which costs more. Newer cold-climate models handle low temperatures better.
How many hours a day should a heat pump run in winter?
In cold weather it can run for long stretches, even most of the day, because heat pumps deliver heat gently. Long run times are normal as long as the house stays warm and the outdoor unit is not iced over.