Heat Pump Not Cooling

A heat pump not cooling shares most causes with a central air conditioner: thermostat settings, a tripped breaker, a dirty filter, a weak capacitor or low refrigerant. It also has one part an AC does not, the reversing valve that switches between heating and cooling. If the vents blow warm air in Cool mode, a valve or thermostat wiring issue is a real possibility. Check settings, power and airflow first.

Last reviewed
STEP 1 OF 2

Find heat pump repair help

Start with your ZIP code and the service you need. Next you add contact details.

Hot day, no cooling

If someone in the home is older, very young, pregnant or has a health condition, move them to the coolest room, use fans with a window open for airflow, offer water, and consider a public cooling center or a relative's home. Signs such as confusion, fainting, hot dry skin or a very high temperature are a 911 call. If the heat pump smells hot, buzzes or trips its breaker, switch it off and leave it off. Any gas smell from a backup furnace means getting outside and calling the gas utility.

Short answer

Confirm Cool mode, fan on Auto and power to the outdoor unit, then change the filter. If the outdoor unit is running and the air is warm, or the unit is silent, a technician needs to test the valve, capacitor, contactor and refrigerant charge.

Safe checks before calling

  • Thermostat modeCool, not Heat or Auto changeover with odd setpoints. Fan on Auto. New batteries if used.
  • Recently replaced thermostat?Heat pump thermostats must be set for the reversing valve type (often labeled O or B). A wrong setting gives heat when you ask for cooling. Check the installer's setup or the thermostat's heat pump menu.
  • PowerIndoor air handler breaker and the outdoor unit's double breaker both on; the outdoor disconnect switched on.
  • AirflowClean filter, open registers, return grilles clear.
  • Outdoor unitFan turning and nothing blocking the coil. Clear weeds and debris.
  • IceFrost on the lines in summer means turn cooling off and run the fan until it melts.

Your system type changes the checklist

  • Central split heat pumpDucted, with an outdoor unit and indoor air handler. Most of this page applies.
  • Ductless mini-splitIndoor heads have their own filters to rinse and a remote with its own mode settings. A blinking light on the head often signals a fault code.
  • Dual fuelHeat pump plus a gas furnace. Cooling problems are on the heat pump side, but the furnace blower moves the air.
  • Packaged heat pumpOne outdoor or rooftop cabinet. Access and roof work can add labor time.
Technician using an electronic leak detector along a copper line set near an outdoor unit

Faults that stop a heat pump from cooling

  • Reversing valveIf it sticks in heating position, the system heats when it should cool. A solenoid coil failure can do the same.
  • Capacitor or contactorCommon summer failures that stop the outdoor fan or compressor. They carry stored voltage and are technician work.
  • Refrigerant leakWeak cooling and icing point to low charge, which means a leak to repair.
  • Dirty outdoor coilOn very hot days a matted coil cannot reject heat, and cooling fades in the afternoon.
  • Compressor problemsOverheating and overload trips, or a worn compressor. Testing decides between repair and replacement.
  • Blower or controlsIndoor blower motor, control board or thermostat wiring issues.

What shapes the repair price

Ask for a written estimate after diagnosis. These factors explain the spread between quotes.

Part and labor timeA capacitor or contactor is a quick swap. A reversing valve or compressor involves brazing and recovering refrigerant.
Refrigerant type and amountRecharging an R-22 heat pump costs more because U.S. production of R-22 stopped in 2020. Newer systems may use R-410A or A2L refrigerants.
When you callAfter-hours and weekend rates vary. Ask before the visit.
WarrantyParts may be under the maker's warranty, especially on newer units. Have the model and serial ready.
AccessRooftop or tight side-yard units can take more time.

Request heat pump repair and describe whether the outdoor unit runs. More price detail is in the heat pump repair cost guide. Symptoms overlap with AC not cooling, which has a quick triage table.

Related services and guides

Pages that continue this topic.

Questions

Will a heat pump work in 100 degree weather?

Yes, heat pumps cool like air conditioners and are rated for hot weather. On extreme days, a system may run constantly and hold the house warmer than the setpoint. If it cannot cool on an ordinary summer day, something is wrong.

Why is my heat pump running but cold air is not coming out?

If the outdoor unit runs but the air is warm, think reversing valve, refrigerant charge or a thermostat setup error. If the outdoor unit is silent while the blower runs, check the breaker, then call about the capacitor or contactor.

How many years does a heat pump usually last?

Many last around 10 to 15 years, depending on climate, maintenance and how many hours they run each year, since a heat pump works in both seasons.

How do I reset a heat pump if it is not cooling?

Turn the thermostat off, switch off the outdoor breaker for a minute, turn it back on and wait about five minutes before choosing Cool. If cooling does not return, a reset will not solve the underlying problem.